TM0605S

Feature
Current Rating:1A
Voltage-Time:23uS
Switching Frequency150KHZ min
11 mm min creepage and clearance distance between PRI&SEC
Coplanarity:0.1[.004]Max
Designed to comply with the following requirements as defined by IEC60601-1(ed)
Amendment 1Providing two means of patient Protection up to a working voltage of 360Vac
Complies with the following requirements as defined by
IEC60950-1,EN60950-1,UL60950-1/CSA60950-1 and AS/NZS60950-1
-Reinforced insulation for a primary circuit at a working voltage of 550Vac
Overvoltage category II,Pollution Degree 2up to 2km above sea level
Designed to comply with the following requirements as defined by IEC60664-1:
-Reinforced insulation for a primary circuit at a working voltage of 400Vac
up to 2km above sea level.
    Feature
    Current Rating:1A
    Voltage-Time:23uS
    Switching Frequency150KHZ min
    11 mm min creepage and clearance distance between PRI&SEC
    Coplanarity:0.1[.004]Max
    Designed to comply with the following requirements as defined by IEC60601-1(ed)
    Amendment 1Providing two means of patient Protection up to a working voltage of 360Vac
    Complies with the following requirements as defined by
    IEC60950-1,EN60950-1,UL60950-1/CSA60950-1 and AS/NZS60950-1
    -Reinforced insulation for a primary circuit at a working voltage of 550Vac
    Overvoltage category II,Pollution Degree 2up to 2km above sea level
    Designed to comply with the following requirements as defined by IEC60664-1:
    -Reinforced insulation for a primary circuit at a working voltage of 400Vac
    up to 2km above sea level.
    Designed to comply with the following requirements as defined by IEC61010-1:
    -Reinforced insulation for a line to neutral voltage up to 1000vrmsovervoltage Category II,up
    to 2km above sea level
    - Reinforced insulation for a line to neutral voltage up to 600vrmsovervoltage Category II,up
    to 5km above sea level
    Complies with the following requirements as defined by IEC62368-1,UL/CSA62368-1 and
    EN62368-1
    - Reinforced insulation for ES3,operating frequency above 30KHZ,working voltage up to
    550Vrms1600Vpeakovervoltage category II,Pollution Degree II,and up to 2km above sea
    level
    Comply with RoHS requirements.
    Operating temperature range:-40 to +125.
    Qualified to AEC-Q200

    Electrical Specifications @ 25℃

    PAPAMETER

    TEST CONDITIONS

    VALUE

    D.C.RESISTANCE           1-3

    @20C

    0. 15ohms max

    D.C.RESISTANCE           6-4

    @20C

    0. 15ohms max

    INDUCTANCE                 1-2

    100KHZ 10 mVac. LS

    110 uH min

    INDUCTANCE                 2-3

    100KHZ 10 mVac. LS

    110 uH min

    CAPACITANCE               1-6

    100KHZ 10 mVac. CS

    18pF max

    DIELECTRIC                   1-6

    6250Vrms 2 seconds

    5000Vrms 1 minute

    TURNS RATIO

    6-4:1-3

    1:1 ±2%